Varioskan™ LUX Multimode Microplate Reader (2023)

VL0000D0full specificationsEveryabsorbance, fluorescence intensityHeadmasternone

Preis:20.900,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesHeadmaster
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionSpectral and absorbance scan: dual monochromator, fluorescence intensity: dual emission and excitation monochromator
precision0.003 Abs o ±2%, from 200 to 399 nm (0 to 2 Abs)
0.003 Abs o ±1%, at 400 to 1000 nm (0 to 3 Abs)
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
height20 The rod
height (metric)51cm
idiots50/60 Hertz
linearity96-well plate: ±2% (0 to 4 Abs at 450 nm)
384-well plate: ±2% (0 to 3 Abs at 450 nm)
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
precisionSD < 0.001 Abs or CV < 0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
voltage100/240 V
wave rankAbsorption: 200 bis 1000 nm
Fluorescence intensity: excitation: 200 to 1000 nm, emission: 270 to 840 nm
weight119 pounds
weight (metric)54kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VLB000GD0full specificationsEveryabsorbance, fluorescence intensityheader and footernone

Preis:26.520,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesheader and footer
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionFluorescence intensity: excitation: 200 to 1000 nm, emission: 270 to 840 nm
absorption area200 bis 1000 Nanometer
Accuracy (photometric)0.003 Abs or ±2% at 200 to 399 nm (0 to 2 Abs), 0.003 Abs or ±1% at 400 to 1000 nm (0 to 3 Abs)
CO2 concentration range0,1 bis 15%
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
Emission wavelength range270 to 840 nautical miles
Excitation wavelength range200 bis 1000 Nanometer
height20 The rod
height (metric)51cm
linearity96-well plate: 0 to 4 Abs, ±2% at 450 nm, 384-well plate: 0 to 3 Abs, ±2% at 450 nm
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
O2 concentration range1 bis 21%
precisionSD <0.001 Abs or CV <0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VL0L00D0full specificationsEveryabsorbance, fluorescence intensity, luminescenceHeadmasternone

Preis:25.340,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity, luminescence
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesHeadmaster
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionSpectral and absorbance scan: dual monochromator, fluorescence intensity: dual emission and excitation monochromator
precision0.003 Abs o ±2%, from 200 to 399 nm (0 to 2 Abs)
0.003 Abs o ±1%, at 400 to 1000 nm (0 to 3 Abs)
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
Luminescence: > 7 decades
height20 The rod
height (metric)51cm
idiots50/60 Hertz
linearity96-well plate: ±2% (0 to 4 Abs at 450 nm)
384-well plate: ±2% (0 to 3 Abs at 450 nm)
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
precisionSD < 0.001 Abs or CV < 0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Luminescence: < 7 amol ATP/well (384-well white plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
voltage100/240 V
wave rankAbsorption: 200 bis 1000 nm
Fluorescence intensity: excitation: 200 to 1000 nm, emission: 270 to 840 nm
Luminescence: 360 to 670 nm
weight123 pounds
weight (metric)56kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VLB000GD1full specificationsEveryabsorbance, fluorescence intensityheader and footer1

Preis:27.580,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
light sourceXenon flash lamp
measurement speed96 wells: 15 s, 384 wells: 45 s, 1536 wells: 135 s.
measuring technologyabsorbance, fluorescence intensity
plate type6 to 1536 well plates, absorbance: 6 to 384 well plates
product lineVarioskan™
reading opportunitiesheader and footer
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate< 2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionDouble monochromators, double excitation monochromators, double emission monochromators
Accuracy (photometric)0.003 Abs or ±2% at 200 to 399 nm (0 to 2 Abs), 0.003 Abs or ±1% at 400 to 1000 nm (0 to 3 Abs)
CO2 concentration range0,1 bis 15%
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
height20 The rod
height (metric)51cm
linearity96-well plate: 0 to 4 Abs, ±2% at 450 nm, 384-well plate: 0 to 3 Abs, ±2% at 450 nm
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donors1
O2 concentration range1 bis 21%
precisionSD <0.001 Abs or CV <0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 to 1000 nm Fluorescence Intensity: Excitation: 200 to 1000 nm Emission: 270 to 840 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VL0L0TD0full specificationsEveryabsorbance, fluorescence intensity, luminescence, time-resolved fluorescenceHeadmasternone

Preis:28.170,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity, luminescence, time-resolved fluorescence
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesHeadmaster
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionSpectral and absorbance scan: dual monochromator, fluorescence intensity: dual emission and excitation monochromator, time-resolved fluorescence: filter
precision0.003 Abs o ±2%, from 200 to 399 nm (0 to 2 Abs)
0.003 Abs o ±1%, at 400 to 1000 nm (0 to 3 Abs)
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
Time-resolved fluorescence: > 6 decades
Luminescence: > 7 decades
height20 The rod
height (metric)51cm
linearity96-well plate: ±2% (0 to 4 Abs at 450 nm)
384-well plate: ±2% (0 to 3 Abs at 450 nm)
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
precisionSD < 0.001 Abs or CV < 0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Time-resolved fluorescence: < 1 amol/well (384-well small volume white plate)
Luminescence: < 7 amol ATP/well (384-well white plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 bis 1000 nm
Fluorescence intensity: excitation: 200 to 1000 nm, emission: 270 to 840 nm
Fluorescence resolution time: excitation 334 nm, emission 400 to 700 nm
Luminescence: 360 to 670 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VLB000GD2full specificationsEveryabsorbance, fluorescence intensityheader and footer2

Preis:28.630,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesheader and footer
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionAbsorption: dual monochromator, fluorescence intensity: dual excitation and emission monochromator
Accuracy (photometric)0.003 Abs or ±2% at 200 to 399 nm (0 to 2 Abs), 0.003 Abs or ±1% at 400 to 1000 nm (0 to 3 Abs)
CO2 concentration range0,1 bis 15%
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
height20 The rod
height (metric)51cm
linearity96-well plate: 0 to 4 Abs, ±2% at 450 nm, 384-well plate: 0 to 3 Abs, ±2% at 450 nm
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donors2
O2 concentration range1 bis 21%
precisionSD <0.001 Abs or CV <0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 to 1000 nm Fluorescence Intensity: Excitation: 200 to 1000 nm Emission: 270 to 840 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VL0LA0D0full specificationsEveryAbsorption, Fluorescence Intensity, Luminescence, AlphaScreenHeadmasternone

Preis:27.720,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp, LED
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyAbsorption, Fluorescence Intensity, Luminescence, AlphaScreen
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesHeadmaster
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionSpectral and absorbance scan: dual monochromator, fluorescence intensity: dual emission and excitation monochromator, AlphaScreen: filter
precision0.003 Abs o ±2%, from 200 to 399 nm (0 to 2 Abs)
0.003 Abs o ±1%, at 400 to 1000 nm (0 to 3 Abs)
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
Luminescence: > 7 decades
height20 The rod
height (metric)51cm
linearity96-well plate: ±2% (0 to 4 Abs at 450 nm)
384-well plate: ±2% (0 to 3 Abs at 450 nm)
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
precisionSD < 0.001 Abs or CV < 0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Luminescence: < 7 amol ATP/well (384-well white plate)
AlphaScreen: < 100 amol Phosphotyrosin/Well (384-Well-Platte)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 bis 1000 nm
Fluorescence intensity: excitation: 200 to 1000 nm, emission: 270 to 840 nm
Luminescence: 360 to 670 nm
AlphaScreen: excitation 680 nm, emission 400 to 660 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VLBL00GD0full specificationsEveryabsorbance, fluorescence intensity, luminescenceheader and footernone

Preis:31.170,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity, luminescence
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesheader and footer
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionAbsorption: dual monochromator, fluorescence intensity: dual excitation and emission monochromator
Accuracy (photometric)0.003 Abs or ±2% at 200 to 399 nm (0 to 2 Abs), 0.003 Abs or ±1% at 400 to 1000 nm (0 to 3 Abs)
CO2 concentration range0,1 bis 15%
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades; Luminescence: > 7 decades
height20 The rod
height (metric)51cm
linearity96-well plate: 0 to 4 Abs, ±2% at 450 nm, 384-well plate: 0 to 3 Abs, ±2% at 450 nm
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
precisionSD <0.001 Abs or CV <0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate); Luminescence: < 7 amol ATP/well (384-well white plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 to 1000 nm Fluorescence Intensity: Excitation: 200 to 1000 nm Emission: 270 to 840 nm Luminescence: 360 to 670 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VL0LATD0full specificationsEveryabsorbance, fluorescence intensity, luminescence, time-resolved fluorescence, AlphaScreenHeadmasternone

Preis:30.500,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp, LED
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity, luminescence, time-resolved fluorescence, AlphaScreen
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesHeadmaster
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionSpectral and absorbance scan: dual monochromator, fluorescence intensity: dual emission and excitation monochromator, AlphaScreen and time-resolved fluorescence: filter
precision0.003 Abs o ±2%, from 200 to 399 nm (0 to 2 Abs)
0.003 Abs o ±1%, at 400 to 1000 nm (0 to 3 Abs)
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades
Time-resolved fluorescence: > 6 decades
Luminescence: > 7 decades
height20 The rod
height (metric)51cm
linearity96-well plate: ±2% (0 to 4 Abs at 450 nm)
384-well plate: ±2% (0 to 3 Abs at 450 nm)
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donorsnone
precisionSD < 0.001 Abs or CV < 0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate)
Time-resolved fluorescence: < 1 amol/well (384-well small volume white plate)
Luminescence: < 7 amol ATP/well (384-well white plate)
AlphaScreen: < 100 amol Phosphotyrosin/Well (384-Well-Platte)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 bis 1000 nm
Fluorescence intensity: excitation: 200 to 1000 nm, emission: 270 to 840 nm
Fluorescence resolution time: excitation 334 nm, emission 400 to 700 nm
Luminescence: 360 to 670 nm
AlphaScreen: excitation 680 nm, emission 400 to 660 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
VLBL00GD1full specificationsEveryabsorbance, fluorescence intensity, luminescenceheader and footer1

Preis:31.660,00

Your price:

-
compatibilityrobot
detector typePhotomultiplier tube (PMT)
Incubator temperatureUp to 45ºC
interfaceSoftware for PC (Thermo Scientific SkanIt software)
light sourceXenon flash lamp
measurement speed15 s for 96 well plate, 45 s for 384 well plate, 135 s for 1536 well plate (minimum times)
measuring technologyabsorbance, fluorescence intensity, luminescence
plate type6-1536-Well-Platte (6-384-Well-Absorptionsplatte)
product lineVarioskan™
reading opportunitiesheader and footer
reading range0 to 6 abs
ShakeOrbital
software typeSoftware ScanIt
Spectral Sample Rate<2.2 s/well 400 to 500 nm, 1 flash, 2 nm step
wavelength selectionAbsorption: dual monochromator, fluorescence intensity: dual excitation and emission monochromator
Accuracy (photometric)0.003 Abs or ±2% at 200 to 399 nm (0 to 2 Abs), 0.003 Abs or ±1% at 400 to 1000 nm (0 to 3 Abs)
CO2 concentration range0,1 bis 15%
Depth (English)23pol.
depth (metric)58cm
dynamic rangeFluorescence intensity: maximum reading > 6 decades; Luminescence: > 7 decades
height20 The rod
height (metric)51cm
linearity96-well plate: 0 to 4 Abs, ±2% at 450 nm, 384-well plate: 0 to 3 Abs, ±2% at 450 nm
Type of measureEndpoint, kinetic, spectra, multipoint, kinetic spectra
number of donors1
O2 concentration range1 bis 21%
precisionSD <0.001 Abs or CV <0.5%, at 450 nm (0 to 3 Abs)
sensitivityFluorescence intensity (upper reading): < 0.4 fmol fluorescein/well (384-well black plate); Luminescence: < 7 amol ATP/well (384-well white plate)
Language versions of the softwareEnglish, German, French, Spanish, Portuguese, Italian, Japanese, Chinese and Russian
wave rankAbsorption: 200 to 1000 nm Fluorescence Intensity: Excitation: 200 to 1000 nm Emission: 270 to 840 nm Luminescence: 360 to 670 nm
weight125 pounds
weight (metric)57kg
Width (English)21pol.
width (metric)53cm
One size fits allEvery
Top Articles
Latest Posts
Article information

Author: Edmund Hettinger DC

Last Updated: 03/04/2023

Views: 6547

Rating: 4.8 / 5 (58 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Edmund Hettinger DC

Birthday: 1994-08-17

Address: 2033 Gerhold Pine, Port Jocelyn, VA 12101-5654

Phone: +8524399971620

Job: Central Manufacturing Supervisor

Hobby: Jogging, Metalworking, Tai chi, Shopping, Puzzles, Rock climbing, Crocheting

Introduction: My name is Edmund Hettinger DC, I am a adventurous, colorful, gifted, determined, precious, open, colorful person who loves writing and wants to share my knowledge and understanding with you.